J&O Fluid

News

Sanitary Valve Material Or Structure Strength Test

Publish Time: Author: Site Editor Visit: 125

After the sanitary valve is installed, it is necessary to test the ability of the valve material or structure to withstand a certain force without damage, which is also called strength test. The strength test of general sanitary valves lasts for 2 to 3 minutes, while some special valves need to last for about 5 minutes. During the test, the valve body and valve cover are not allowed to leak or sweat.

Sanitary Valve Strength test method:

1. Before the test, it is necessary to confirm that there are no cracks, slag inclusions and other defects in each component to avoid affecting the test results.

2. Performing a strength test after rough processing of the components can effectively avoid or reduce losses.

3. During the test, the sanitary valve is opened, leaving a port for medium input and applying pressure

4. The strength test pressure is generally P=1.25*PN

After the sanitary valve is tested for the ability of the valve material or structure to withstand a certain force without damage, if there is no leakage or sweating within the specified time, it can be identified as a product that has passed the strength test. For leaking valves (except for valves that are allowed to leak as specified), you can choose to re-weld them and then conduct strength tests again, or you can choose to scrap the unqualified products.

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.